Hi Jennifer, power down (shut off the breaker) again, to see if it will switch back. I replaced T104 timer it runs and shuts off with no issue but once off the timer does not move or turn back on. Is it Necessary? Until it came in, I manually turned on and the tripper turned it off. I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. Electricity is dangerous and can kill you if you dont know what youre doing. 120Volt Tork 1101 timers can be fixed with repair parts. If your Intermatic swimming pool timer has stopped working you will have to do something called troubleshooting. Should it still not work, I suspect a motor failure for the clock. I have an intermatic timer thats 2 years young. Jump to the troubleshooting steps below to fix the issue. Just some ideas. Hi there, You dont have two OFF trippers, right? Hello have a question some what related. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. Or fold the cover to one side if needed. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Next step would be to inspect the wires going from timer to pump motor, or test them for continuity. Hi Davy, "@type": "ImageObject",
Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. If they are not moving then you have an issue. How can it keep time if lever is in off position (manual lever). Today is the second day that I have had to turn it on manually. Reset the clock on the timer to the correct time to get it back to the desired on/off times. "address": "",
I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. If youve followed this guide or arent confident in diagnosing the issue yourself, seek a qualified pool technician or electrician. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. Any other thoughts? Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Is the dial bent or warped? We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. The 2,810 sq. It worked for a day but the day after it didnt work. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Clock wont move, gear dont move at all. Thanks. Would I suspect this is a defective motor? I bought a new timer and replace the T104 timer clock. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool That will do it. There is power; gears are moving. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Hi Rhomell, are you sure you got the correct trippers? Perhaps you had a power outage during the night? Still no luck. My intermatic pool timer will not automatically turn on. I - JustAnswer It stays on until I turn off the circuit breaker. You can turn off Freeze protection and it should stop, or replace the probe if faulty. Copyright 2022 In The Swim. I bought a new motor for mine after 20 years and learned about this the hard way. "logo": {
Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. },
Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Hi, Davy, seeing lots of complaints here. Pool Timer Clock Parts and Trippers Welcome to Pool Spa Outpost! Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. First time pool owner, Pool timer and trippers not working properly! Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. A recent power outage will cause the timer to stop working. Then after a bit, the pump restarts. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. Is this a bad timer mechanism or loose wire? LIMITED TO A ONE-TIME RUN OF 666 UNITS. We cover T101, T103 and T104 models of mechanical pool timers. The most common pool timer used for inground pool pumps is the Intermatic time clock. As you release the dial, you will feel the gears engage. Pop-in a new timer mechanism, and replace the wires to the previous configuration. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Hi Matthew T104 can only turn one pump on and off. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Leave the paper inside your timer box so that you do not mistakenly misplace it. Or other advice or explanation. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Hi Rich, is one of those wires (white?) Now remove the terminal cover on the timer. I had the exact same thing happen recently. Please let me know if you find the solution! TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. The mechanism for the off tripper doesn't work at all when manually depressed. You will first want to look at the pool timer and see if you have two timer pins. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) I can, however, hear an intermittent click as if the mechanism is trying to switch on. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Followed all directions and even watched YouTube troubleshooting videos. Theres power to the pump using the manual override. The timer not working is for the pump. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. P.S. Thank you. Are the trippers slid all the way onto the dial fully? I hope this helps. Could I send you a picture of my setup? Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Ive reset the time 5 times and just realized that its going counter clockwise. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). What Causes Problems With Intermatic Timers? - Reference.com Inside, the 1 gear on the right side can be removed to access a metal bar. During this the pump cannot be manually switched on. Can the pool timer be placed inside the garage to protect it from the harsh weather. Wont work manually or by timer function. Black goes to _1 These clocks determine when your pool pump turns on, and how long it runs. Intermatic Pool Timer, tips & troubleshooting - YouTube Now ever sense I did that last week my timer wont shut off or turn on my pool pump. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. When I turned it back on now the pool clock goes backwards. "name": "In The Swim",
If power is coming to the timer motor, you will clearly see the gears moving through the small window. You can also apply some of the troubleshooting steps to other brand timers. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. First, verify the power is turned off at the breaker panel. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. "@type": "Person",
I noticed that the on flipper was a little bit bent so I replaced it with new one. Any advice? How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Does the tripper work on other areas of the clock, like near the off tripper? Switch the breaker off at the power board. I went to the control panel and saw that the timer needle stopped just after the start pointer. Can I wire this timer to an outlet or should I search for another solution? My timer clock does not run and the manual on off switch does not turn off the pump motor. i have a P1121 intermatic timer connected to a hayward above ground pool pump. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Tork Pool Timer does not trip on - JustAnswer Or is there anything else I can check? Take them off and inspect them. AJH Trade Group also participate in other affiliate programs. Replace a new T104. The 10 Best Pool Timers - Pool Care Guy First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. Any ideas? There could also be other mechanical reasons for this happening, such as a disconnect in the switch. I bought new trippers. Slide it around the pool timer dial to the correct start time and re-tighten it. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Then remove the mechanism by pressing the clip at the top of the timer box. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. Paul, it could be that you got a 50hz motor, instead of a 60hz? Intermatic timer won't turn on/off pump. | Trouble Free Pool I had a thunderstorm last night and my power went off for like 3 hours. I have Model T40004RTe. After a power failure the timer clock can start up backwards, mine has done this several times. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. Timer not tripping pump on. Here are some pictures. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. please help me. You should be able to see the gears moving. on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Pool pump timers can last up to 20 years, depending on the model. Trippers are not installed properly Re-install trippers on dial 2.
Bungee Fitness Equipment For Home,
What Is A Junior Ticket Ticketek,
How Old Was Mariah Carey In Heartbreaker,
Zero Lot Homes In Collierville, Tn,
Articles P
pool timer trippers not working More Stories